: M302 Just got the extruder motor to work with G1 E1 F100 andG1 E-1 F100. com ], E3D tool changer, Robotdigg SCARA printer, Crane Quad and Ormerod. So when i home it, x and y go to 225 and z goes to 0. yello3d. Try sending M302 S0 or M302 P1 to the printer to disable that and try the port again. Extrude a small amount to ensure that your extruder motor is on and holding. Crypto@gloomyandy are these values incorrect?; Tools M563 P0 S"volcano" D0 H1 F0 ; define tool 0 G10 P0 X0 Y0 Z0 ; set tool 0 axis offsetsExtruder SKR2 not spinning. one immediately before X). droftarts administrators @flyscha last edited by . 0. J'y connais pas grand chose dans les imprimantes 3D, moi jusque là, ça fonctionnais donc je ne m’intéressai pas trop au reste, mais là, je suis bien obligé, et donc je ne sais pas faire la commande G-code que tu m'indique, ou faire ça dans Repetier-Host ?We are using two different kinds of motors, but for the Z and E we are using we are using Nema 23 bipolar 2. It should be possible to make a Gcode file in a text. M302 P1 will disable the temperature check that disables the extruder when the nozzle is cold. M302 P1 ; Allow cold extrusion M82 ; use absolute distances for extrusion G92 E0 ; Reset Extruder G1 E-430 F3600 ; retract 430 mm M302 P0 ; Disable cold extrusion T-1 P0 ; Deselect all tools without running any tool change macros. I have been clicking the 'retract' and 'extrude' button multiple times to push the plunger down to the correct position and to retract the plunger from the bottom of the cylinder after the print. g. Suppose they are, in fact, 105mm apart. M302 P1 M563 P0 D0 T1 ;enable cold extrusion. 1 Reply Last reply Reply Quote 0. Set the temperature (and. In order to report the current status, run. . Always getting "ERROR: Preheat the Nozzle!". Then reduce the distance, and stop just before the filament disappears into the hot end. . Any help would be greatly appreciated. This topic has been deleted. 1 Reply Last reply Reply Quote 0 droftarts administrators @flyscha last edited by M302 P1 ; allow cold extrude M302 S0 R0 ; allow cold extrude;M563 P1 P3 S"filament" D1 H1 H3 F4 ; define tool 1;G10 P1 X0 Y0 Z0 ; set tool 1 axis offsets;G10 P1 R0 S0 ; set initial tool 1. You want to leave that in case the bed or anything else still has a heater, and it wouldn't fix your problem anyway. 7 Move a motor on delta printer On delta printers, the X,Y and Z movements does not correspond to a motor movement, while for commissioning, you may want to operate each motor. Heater 1 fault: temperature rising too slowly: expected 2. M302 S60 (for M3 and M2 Series printers) M302 P1 for (for Ultra One printers) (this allows the printer to extrude with the hot end above 60 degrees and is only a temporary change). Looking for a way that is super native, standalone and low end way to get it to do that without using high level programming architecture, such as not using software that is running on python or what not. If the motor doesn’t turn then check for the Steps/mm setting to see if it got. Serial No. To test for this, with the power off swap the E0 connector on the Duet with another one e. M950 F0 C"fan0" Q500 ; create fan 0 on pin fan0 and set its frequency. I would be very gratefull for any help. GameStop Moderna Pfizer Johnson & Johnson AstraZeneca Walgreens Best Buy Novavax SpaceX Tesla. Connector for the extruder is plugged into second connection (i. wordpress. Expected behavior: The Unload should ignore the temperature on the Hotend and do its. It works perfectly fine on RRF2 though. For example you can create a Macro for "Allow Cold Extrude" to call M302 P1. What could be the causeMarlin defaults to "no cold extrusion". M584 X0. M302: Allow cold extrudes add cancelling of the command; M561: Set Identity Transform - reset the transformation from calibration; Non specific G-codes Movement. @jfavre said in Extruder motor not working. @agent0810 said in Homing advice: the z is at 0 at the top, so it cant go lower right? shouldnt it home at 300 something? im having issues moveing the bed. How would I know to send a T0 and then M302 P1 to test the extruder? Quote dc42 Make sure you have a tool selected (e. config. M302 P0. the X motor. I just wondered if there was a way of "embedding" it in the config files so that it runs by default. 0024. I need to print some PCL filament, which melts optimally at 100 C°. 4. (You'll need to pull hard sometimes) Step 7 Printer: Anycubic Chiron, Firmware: Marlin 2. G1 E20 moves E0 as expected T1 changes tools as expected G1 E30 move E1 as expected. M302 P1 ; Allow Cold extrudes M98 Pmachine_maxtemp. When the punch inlet sensor (PS301) detects paper fed from the upstream connection machine, the punch shift motor (M302) drives, and the punch slide unit starts moving to the rear. Volume 2. This value gives better accuracy at typical printing temperatures in the range 190 to 250C than the B value of 4267 quoted in the datasheet. M302 P0 S170. M302 P1 Now advance the filament using the jog buttons on the Manual Control tab, until it reaches the top of the heatsink. Set nozzle and bed temperature to something below 30°C so the hotend fan wont spin up. I'm attempting to drive I was successful in driving a Maxon DC motor with encoder (pulled from a Stratasys Dimension 1200es BST) with a Duet 2 Wifi via a Geckodrive G320x. . Ralms @fcwilt 8 Aug 2020, 08:57. g. Here is my diagnostic file and my config. Re: How can I move E steppers? January 11, 2023 02:36AMSolved; M302 P1 command I have a duet2 wifi that I'm working on. @2:0 SENT: M302 RECEIVED: ok 0 RECEIVED: Cold extrusion allowed RECEIVED: wait Zum Test verwende ich immer Folgendes: G91 G1 E500 F3000 1-mal bearbeitet. I'm attempting to drive I was successful in driving a Maxon DC motor with encoder (pulled from a Stratasys Dimension 1200es BST) with a Duet 2 Wifi via a Geckodrive G320x Digital. droftarts administrators @flyscha last edited by . I probed the STEP output with an oscilloscope and the pulses are there and the pulse length is fine. Compared with the other two materials, this conformal metasurface has the best ability to bend. My request is to add a connection to the Marlin firmware as it is done in program "LaserGRBL" Your GRBL_Plotter program is very good, adding this function would make it even. @o_lampe said in Error: Driver 5 does not support x1 microstepping: M584 X0 Y1 Z2 E5 ; set drive mapping M569 P5 S1 T25:25:25:25 ; physical drive 5 is external (DUE) M350 E1 ; no microsteps,. M302 Allow Cold Extrudes [Pnn/Snn/Rmm] Allow cold extrude, set min extrude & retract temps M302 P1 ; Allow cold extrusion M552 Set IP, enable/disable network in[Pnn / Snn/ Rnn] P(IPV4 address) S(0|1 enable|disable, M552 S1 P192. If that's not the case, we need to change the direction of rotation. See: Promega SupportBusiness, Economics, and Finance. g underneath: M122 === Diagnostics === RepRapFirmware for Duet 3 Mini 5+ version 3. Send G1 E100 F200 to extrude 100mm of filament. I made my own slicer for the concrete printer, but for some reason the layer change is not detected, so my "Last Layer Time" is not updated. Sending M302 P1 shows green as though it accepts the command, but the extrude & retract buttons are still grayed out. 2. 155 5. There is no minimum steps/mm set in the firmware. This topic has been deleted. @patel said in how to change homing sequence: corexy printer setup how to change sequence homing x,y i am using M3D promega and i need to change sequence first y axis home after x axis manual working fine by hand trigger switch x limit and y limit See h. ; Heaters;M143 H1 S260 ; Maximum heater temperature M140 H-1 ; No bed heater;M305 P1 T100000 B4138 C0 R4700 ; Thermistor parameters for heater 1;M307 H1 A577. Actual. Other possible causes are a bad stepper motor or cable. Heaters, 24v 40W - Im using 24V 400watts power supply. It's deadly accurate and offers a 3 shot kill at the cost of effectiveness at closer ranges. Pix4d often makes vertical surfaces to 45 deg where they meet the ground. M302 P1 ; enable cold extrusion G4 S1 ; wait for one second G1 E15 F500 ; load filament inside the gears M109 S235 T0 ; set hotend temperature and wait G1 E200 F500 ; extrude 200mm, you may need to reduce speed for. Thermostatic control is turned off ; Fan for the hotend M950 F1 C"out6" L0:1000 Q50 ; create fan 1 on pin out6 and set its frequency M106 P1 S1 H1 T45 C"Hotend" ; set fan 1 value. Crypto‘M302 P1 ; disable cold extrusion checking’ 2. In that case, you might use M302 S65 or similar to drop the MIN_TEMP. What is the trigger word to tell the firmware that we are starting a new layer? KulitorumHow bout if you heat up the hotend to 180?Hi *, I hope that somebody can help me here. 00 and cannot get the stepper motors of the extruders to work. Equipped with a remote controller designed for enterprise users and the newly upgraded Pilot 2 flight app, to improve the efficiency of drone operations. If calibrating cold: Bowden: Disconnect the bowden tube from your extruder. Only users with topic management privileges can see it. I have to turn the power off and on to reset it. M569 P1 S0 ; physical drive 1 goes forwards using default driver timings M569 P2 S1 ; physical drive 2 goes forwards using default driver timings. HI again, what I'm doing wrong, the extruder buttons in DWC won't be gray, its grayed out. Then reduce the distance, and stop just before the filament disappears into the hot end. As well as selecting the tool with e. To test for this, with the power off swap the E0 connector on the Duet with another one e. 12/28/2022, 7:25:14 PM M302 Cold extrusion is allowed (use M302 P0 to forbid it) 12/28/2022, 7:25:05 PM M302 P1 12/28/2022, 7:23:58 PM M302 Cold extrusion is forbidden (use M302 P1 to allow it), min. I am at a loss for next step. 3 (3. it has a bowden setup and i have the bowden tube off. 0. It will not move when the hotend is cold as a safety feature in the firmware. 12/28/2022, 7:23:58 PM M302 Cold extrusion is forbidden (use M302 P1 to allow it), min. Heating Bed manually by G-Code. Send M302 P1 to allow Cold extrusion; Send M600 T1 to initiate Filament swap; Follow the Instructions on the Screen. The belts are not over tight. 3 ; Filter. It was type 5 in marlin. Home page Shop all products. -> no reaction at all - even after "M302 P1" What is working: Homing. Expected behavior: The Unload should ignore the temperature on the Hotend and do its thing. I used to use "Pronterface" for that. g. P1: Stroke: CT/CTA should also be considered; Appendicitis: MRI rarely indicated. wordpress. 5beta2 regarding the 'M302 P1' cold extrusion command. Technical Explanation 1. : Heater 1 fault: temperature rising too slowly: expected 2. I would be very gratefull for any help. M302 P1 ; disable cold extrusion checking And yes each extruder is a tool T0 G1 E20 ; move current extruder 20mm T1 G1 E20 T2 G1 E20 Edited 2 time(s). Viko. is not colored in WebControl as in the example screenshots i saw. 1 OS hope it might work on it. After I have executed the M302 S1 command, the extruder moves a few steps in one direction and then stops. Re: Help with extruder feed calibration -. 4 S240 M307If calibrating cold, run M302 P1 (allows cold extrusion) If calibrating hot, heat your hotend to printing temp. In order to report the current status, run. 9mm of feed stock. To test for this, with the power off swap the E0 connector on the Duet with another one e. Here is a handy list of g-code commands Reply Quote. retraction temperature 90. G10 P1 X0 Y0 Z0 ; Set tool 1 axis offsets G10 P1 R0 S0 ; Set initial tool 1 active and standby temperatures to 0C M302 S120 R110 ; Allow extrusion starting from 120°C and retractions already from 110°C Failure to extrude in RepRapFirmware is usually caused by either cold extrusion prevention (but you have sent M302 P1 to disable that), or not having the tool selected. 0C. You could also put those commands in a normal text file with the file ending ". Reply Quote. @droftarts OK, I wish I knew which of the changes finally mattered but I don't. Sending T0 initiates the heater and then faults out. yello3d. However, I can't get the servo running with the new firmware. The SMuFF is supposed to beep for 1 second. Only users with topic management privileges can see it. M302 P1 ; disable cold extrusion checking And yes each extruder is a tool T0 G1 E20 ; move current extruder 20mm T1 G1 E20 T2 G1 E20 Edited 2 time(s). The button movement range is about 0. To test for this, with the power off swap the E0 connector on the Duet with another one e. Unfortunately, the paper did not have anything about the exact settings. . Other possible causes are a bad stepper motor or cable. droftarts administrators @flyscha last edited by . M569 P1 S1 D3 V0 ; Drive 1 goes forwards, CoreXY_2, stealth chop, disable spread cycle M569 P2 S1 D3 V0 ; Drive 2 goes forwards, Z Motor, stealth chop, disable spread cycle. 3. Set the temperature (and enable) using. Ok if the motor is confirmed working, then at least cold extrusion should allow it to extruder as long as the tool is actually selected. I drive them with: M906 X1000 Y1000 Z1000 E900 I30 One of the steppers starts skipping since some days and I'm unable to find the reason. Failure to extrude in RepRapFirmware is usually caused by either cold extrusion prevention (but you have sent M302 P1 to disable that), or not having the tool selected. Only users with topic management privileges can see it. Large delta printer [miscsolutions. : M302 Just got the extruder motor to work with G1 E1 F100 andG1 E-1 F100. gcode" and run that from an SD card. With steps/mm so low you will get nothing like enough torque out of your motor to extrude anything, unless it is a really huge motor. 00 and cannot get the stepper motors of the extruders to work. extrusion temperature 160. G1 E20 moves E0 as expected T1 changes tools as expected G1 E30 move E1 as expected. Once satisfied the extruder drive is working, re-enable cold extrusion prevention using the following command: M302 P0 Reset the Active temperature for Heater 1 back to 190C. M302 P1;G92 E0. A typical piece of GCode sent to a machine running RepRapFirmware might look like this (The meaning of these codes (and more) is. and forward - so we have are at the point we wanted to be without. M302 P1 (This will revert the next time you reset or power off the Duet, or you can send ‘M302 P0’. Example output if disabled: echo:Cold extrudes are disabled (min temp 170C) Example output if enabled:M581 P1 T2 S0 R0 ;define trigger for filament auto load triggers trigger2. M302 P1 (This will revert the next time you reset or power off the Duet, or you can send ‘M302 P0’. This code and 3D models allow you to make a chess robot out of your 3D printer. M302 P1 allows cold extrusion (RepRapFirmware). 0. M302 P1; Axis Limits M208 X-50 Y0 Z0 U0 S1 ; set axis minima M208 X210 Y220 U260 Z200 S0 ; set axis maxima ; Endstops M574 X1 S1 P"io0" ; configure switch-type (e. 5. Re-enable with. Example output if disabled: echo:Cold extrudes are disabled (min temp 170C) Example output if enabled: To temporarily disable the MIN_TEMP, you need to run the G-code M302 P1 or M302 S0 - M302 on its own does nothing. M570 S180 ; allow it 180 seconds before gving a heating warning and test hotends wont be tuned. . 5 (2022-11-30 19:41:16) running on Duet 3 Mini5plus WiFi (SBC mode)M302 P1 ; cold extrude: G92 × 0 Y0 Z0 ; set current position to {X = 0,Y = 0,Z = 0} G92 E0 ;zero the extruded length: G1 F200 E0. This will hopefully make it a bit easier for me to. Here is a handy list of g-code commands [ reprap. GameStop Moderna Pfizer Johnson & Johnson AstraZeneca Walgreens Best Buy Novavax SpaceX Tesla. So no need to use M302. 0:0. Saying G0/G1 insufficient homing What could be the reasonThis topic has been deleted. This topic has been deleted. Step 6. Re: Help with extruder feed calibration -. P1: Acute abdominal pain (e. I have a setup similar to the ANET A8. +Z should move the bed down. M302 P1 ; enable cold extrusion M201 E1000 ; reduce extruder acceleration M915 P3 S10 F0 R0 ; set stall detection threshold M913 E100 ; set extruder motor to reduced % current M83 ; relative extrusion G1 S1 E800 F3600 ; move fast 500mm of filament M913 E100 ; set extruder motor to full current M302 P0 ; disable cold extrusion G1 E50 F300. 0. Sending M302 P1 shows green as though it accepts the command, but the extrude & retract buttons are still grayed out. Without inserting the wire I tried to make a print and the extruder works. g. To temporarily disable the MIN_TEMP, you need to run the G-code M302 P1 or M302 S0 - M302 on its own does nothing. GCode and RepRapFirmware. Agisoft less so, but still worse than Terra. The prototype was outsourced to Oshpark. Sending M302 P1 shows green as though it accepts the command, but the extrude & retract buttons are still grayed out. 12/28/2022, 7:23:58 PM M302 Cold extrusion is forbidden (use M302 P1 to allow it), min. There is a web tool for this here which can make this easier for configuring another printer. 16 07:24. To print at this lower temperature, g-code command M302 P1 was used to disable the printer’s cold extrusion checking. g. It may have allowed the extruder to run on the 6HC but I'm thinking the DWC may have still been blocking the sending of any extrude or retraction presses while it looked only at the temperature before enabling the sowtware buttons. The prototype was outsourced to Oshpark. one immediately before X). Only users with topic management privileges can see it. M302 works fine in a starting script or sent via console. 3 ; Cold-Section fan. This manual can be used as an EIA/ISO programming manual. To test for this, with the power off swap the E0 connector on the Duet with another one e. . g ; set bed and extruder max temperatures; --- SECTION: FANS ( ) ---M106 P0 S0 I0 F4 H-1 L0. However,. CryptoAs well as selecting the tool with e. Don't forget to send M302 P0 later to restore normal safety. g ; set bed and extruder max temperatures; --- SECTION: FANS ( ) ---M106 P0 S0 I0 F4 H-1 L0. 3 mm and released @ about 0. M83 ; set extruder to relative mode echo "Start" G1 E60 F150 ; Extrude 60mm at 2. So are you still getting phase errors, or is that resolved? @jfavre said in Extruder motor not working. . I would be very gratefull for any help. droftarts administrators @flyscha last edited by . M302 P1 M584 E3:4;M563 P0 D3:4 ; Define tool 0 (no heaters assigned);M567 P0 E1:1;M584 E3:4;M302 P1 ;COLD EXTRUSION ON; Network M550 PXTP1 ; Set machine name M540 PBE:EF:DE:AD:FE:ED ; Set MAC address M552 P0. 06. Send T0 in the gcode console and check the buttons again. For coding you should add M302 P0 to your ending gcode to re-enable the safety at the end of the file. M569 P0 S1 ; Reverse the X motor M563 P0 D0 H1 ; Define tool 1 G10 P0 S0 R0 ; Set tool 1 operating and standby temperatures M563 P1 D1 H2 ; Define tool 2 (un-comment this for dual nozzle machines) G10 P1 X19 S0 R0 ; Set tool 2 operating and standby temperatures (un-comment this for dual nozzle machines) M92 E447:447 ; Set. M122 shows some weird. Re: Extrude without a Hotend May 04, 2017 11:25PM. Ok I will try the. 0 ; set drive mapping M350 X16 Y16 Z16 E16 I1 ; configure microstepping with interpolationThermostatic control is turned on > 45C turn on ;M106 P1 S255 H-1 M302 P1 ; Allow cold extrusion (for testing) T0 ; Set tool 0 (default extruder) G21 ; Work in millimetres G90 ; Send absolute coordinates. Fix the actual problem, which is that Marlin has a safety feature to protect the extruder and hotend by preventing extrusion when the temperature is below a certain margin. 1. Extrusion Control in DWC unavailable, even after M302 P1. 30 caliber carbine cartridge from 15-round and 30-round detachable box magazines. Failure to extrude in RepRapFirmware is usually caused by either cold extrusion prevention (but you have sent M302 P1 to disable that), or not having the tool selected. 5 fans I have it doing all zeroing and even bed tramming! Awesome to see it tram a skewed-. 5 and 1. the X motor. M302 ; report current cold extrusion state M302 P0 ; enable cold extrusion checking M302 P1 ; disable cold extrusion checking M302 S0 ; always allow extrusion (disable checking) M302 S170 ; only allow extrusion above 170 M302 S170 P1. 3. 1 Reply Last reply Reply Quote 0 droftarts administrators @flyscha last edited by G10 P1 X0 Y0 Z0 ; Set tool 1 axis offsets G10 P1 R0 S0 ; Set initial tool 1 active and standby temperatures to 0C M302 S120 R110 ; Allow extrusion starting from 120°C and retractions already from 110°C Sending M302 P1 shows green as though it accepts the command, but the extrude & retract buttons are still grayed out. @agent0810 said in Homing advice: but then when i tried to home it sent the bed to the bottom Then we need to change the motor direction for Z like we did for the X and Y. Re: How can I move E steppers? January 11, 2023 02:36AMI used the safety scissors to cut off the fingers of the severed hand then tried to give her the fingers. With steps/mm so low you will get nothing like enough torque out of your motor to extrude anything, unless it is a really huge motor. If you want to test your extruder, you can disable cold extrusion prevention using M302: M302 P1. M302 P1 ; Allow Cold extrudes M98 Pmachine_maxtemp. M302. 00°C/sec When you try to heat does the LED near the heater terminal actually turn on? Can. 3 ; Filter. 3 (3. Re: How can I move E steppers? January 11, 2023 02:36AMFailure to extrude in RepRapFirmware is usually caused by either cold extrusion prevention (but you have sent M302 P1 to disable that), or not having the tool selected. 0 Y0. M302 P1 ; Allow Cold extrudes M98 Pmachine_maxtemp. Cannot get extruder motor to respond. g ; Unload to above y-splitter. +Z should move the bed down. Other possible causes are a bad stepper motor or cable. 8 S1. Only users with topic management privileges can see it. I can't move the cold extruder to load the wire. For example you can create a Macro for "Allow Cold Extrude" to call M302 P1. ) You can feed filament at 800mm/m (web interface max speed is 240mm/m),. 042". g. Macros also allow for naming gcodes with easier to remember names. I have some fillamentum wood filament, according to the website print temperature: 170 - 185 °C, however nothing prints within this range. Large delta printer [ miscsolutions. Why happening freezes while running this g-code? G28 ; Homing T0 ; Select tool T0 M83 ; Extruder to relative mode M302 P1 ; Allow cold extrudes G1 X20 F9000 G1 X80 E1 F9000 ;freeze G1 X120 F9000 G1 X80 E1 F9000 ;freeze G1 X20 F9. T0, you need to either heat up that tool, or enable cold extrusion by sending M302 P1. Just need to find settings for Slice Engineering 300c thermistor, the temp reading slightly higher than actual measured with an TC thermometer. ; Tool definitions M563 P0 D0 H1 ; Define tool 0 M302 P1 ; Allow cold extrusion M140 H-1 ; Bed Off;Misc M83 ; Set extruder to relative mode M302 P1 ; Allow cold extrudes. Send T0 in the gcode console and check the buttons again. is not colored in WebControl as in the example screenshots i saw. 0 S1 ; Enable network and acquire dynamic address via DHCP M586 P0 S1 ; Enable HTTP M586 P1 S0 ; Disable FTP M586 P2 S0 ; Disable. GameStop Moderna Pfizer Johnson & Johnson AstraZeneca Walgreens Best Buy Novavax SpaceX Tesla. M302 P1 which just disables temperature checking. microswitch) endstop. G92 X0 Y0 Z0 ; set current position to {X=0,Y=0,Z=0} G92 E0 ;zero the extruded length. M302 P1;M563 P0 D3:4 ; Define tool 0 (no heaters assigned);M567 P0 E1:1;M584 E3:4;M302 P1 ;COLD EXTRUSION ON; Network M550 PXTP1 ; Set machine name M540 PBE:EF:DE:AD:FE:ED ; Set MAC address M552 P0. Thanks. Sort By. M302 P1 disables the cold extrude safety. M302 P1 M584 E3:4;M563 P0 D3:4 ; Define tool 0 (no heaters assigned);M567 P0 E1:1;M584 E3:4;M302 P1 ;COLD EXTRUSION ON; Network M550 PXTP1 ; Set machine name M540 PBE:EF:DE:AD:FE:ED ; Set MAC address M552 P0. G1 E200 F500 ; extrude 200mm, you may need to reduce speed for very soft TPU. yello3d. If you unload it first, you can safely send M302 P1 to permit the extruder to work without heating up the hotend. 2. droftarts administrators @flyscha last edited by . The extruder can't always move as fast s the other axes, that's why my examples to move E use a slower speed (F value). Business, Economics, and Finance. 16 07:24. G28: home all axes. M302 P1 ;allow cold extrusion T0 G1 E1000 F3600 ;new step/mm = old*1000/Measured ;example 1024 measured with old steps = 310 -> new = 310*1000/1024 = 302. 0. 0 C199. the X motor connector. : Just need to find settings for Slice Engineering 300c thermistor, According to this document, you need to use the following in your M308 T100000 B4680 C6. G11: Unretract Used while Firmware retraction is configured in your slicer, along G10@gloomyandy are these values incorrect?; Tools M563 P0 S"volcano" D0 H1 F0 ; define tool 0 G10 P0 X0 Y0 Z0 ; set tool 0 axis offsets G10 P0 R0 S0 ; set initial tool 0 active and standby temperatures to 0CDoes the interface not respect M302? Hi! Can't figure out how to turn the e axis using the lcd knob while the extruder is cold. Zuletzt am 03. So please send T0 and M302 P1 and then see if you can send G1 E1 F100 to make. The 3D models contain files for a mechanical gripper that attaches to the print head of the printer and can move chess pieces around. ; Configuration file for Duet WiFi (firmware version 2. e. droftarts administrators @flyscha last edited by . . 3 E40 ; set drive mapping. For coding you should add M302 P0 to your ending gcode to re-enable the safety at the end of the file. . If calibrating cold: Bowden: Disconnect the bowden tube from your extruder. @patel said in how to change homing sequence: M3D promega There's a full guide to this on M3D's Promega support pages. 5mm/sec echo "Done" M82 ; set extruder to abs modeM302 P1 ; allow cold extrusion. I thought I was having problems outputting STEP and DIR to the G320x, but actually it was a current issue in 3. M302 P0 ; disable cold extrusion M291 P"Filament autoload complete!" S0 T3 ; display message . 00" standard bore "competition" gasket for cast iron or aluminum cylinder heads on 302 and 351W production blocks. Viko. Only users with topic management privileges can see it. Now I would like the printer to pause a print when the printer is running out of clay using an mechanical endstop. I can get the x,y,and z motors moving in pronterface, but the extruder…@jfavre said in Extruder motor not working. 168. 4 card. zip. M302 P1 ; enable cold extrusion. This topic has been deleted. Your config files updated for bugfix Configuration. May 04, 2017 11:25PM. Retract 150 mm of filament, then remove it from the filament drive. Can not get E0 to extrude, M302 P1 = still grey buttons I can't help you with fans on RADDS, but "Attempting to extrude with no tool selected" means just that. Direct drive: Remove your nozzle, hotend, or extruder. I reduced. x) G92 A-1 B-1 ; Make Zrot & Tilt active G1 A0 B0 ; 3. To test for this, with the power off swap the E0 connector on the Duet with another one e. plan view. 1 Reply Last reply Reply Quote 0. Trying to figure out why I can't run my extruder. 8 amps (JK57HS56-2804) with gear boxes for extra power. 28" ; configure active-high endstop for low end on Y via pin null; Z-Probe M558 P0 H5 F120 T6000 ; disable Z probe but set dive height, probe speed and travel speed M557 X15:215 Y15:195 S20 ; define mesh grid M308 S0 P"P0. I read up on the on "Connecting endstop switches - What might go wrong" and then I corrected the wiring and all is good with that. Business, Economics, and Finance. This is the case even with M302 P1 at the bottom of the config. g on the SD card (you can do this in the web interface). 5. retraction temperature 90. Failure to extrude in RepRapFirmware is usually caused by either cold extrusion prevention (but you have sent M302 P1 to disable that), or not having the tool selected. M302_P1_COLD_E. 12/28/2022, 7:23:58 PM M302 Cold extrusion is forbidden (use M302 P1 to allow it), min. Slic3r 1. I cleaned it up today, swapped the nozzle and homed it to make sure nothing seemed…This is a prettified version of the Repetier-Firmware for AVR supported GCodes and MCodes as extracted from Repetier. g ; go to purge bucket. . 1 Reply Last reply Reply Quote 0. but if i want -z to go down shouldnt 0 be at the bottom? how would i swap that around, change the motor direction like you suggested in your last post?I did try a cold extrude M302 P1. However, a steps/mm value of 5. I'm not sure if this gets cancelled at power off. And, for swapping purposes, don't forget the extruder motor/cable/port. M569 P0 S1 ; Reverse the X motor M563 P0 D0 H1 ; Define tool 1 G10 P0 S0 R0 ; Set tool 1 operating and standby temperatures M563 P1 D1 H2 ; Define tool 2 (un-comment this for dual nozzle machines) G10 P1 X19 S0 R0 ; Set tool 2 operating and standby temperatures (un-comment this for dual nozzle machines) M92 E447:447 ; Set. To test for this, with the power off swap the E0 connector on the Duet with another one e.